Pass "start_idx" to plat_scmi_clock_rates_array.
This parameter is required to obtain the rate table
a second time.
Signed-off-by: XiaoDong Huang <derrick.huang@rock-chips.com>
Change-Id: I97c6751e7d34c839ced8f22bddc39fb534978cc4
This change implements platform services for stm32mp1 to expose clock
and reset controllers over SCMI clock and reset domain protocols
in sp_min firmware.
Requests execution use a fastcall SMC context using a SiP function ID.
The setup allows the create SCMI channels by assigning a specific
SiP SMC function ID for each channel/agent identifier defined. In this
change, stm32mp1 exposes a single channel and hence expects single
agent at a time.
The input payload in copied in secure memory before the message
in passed through the SCMI server drivers. BL32/sp_min is invoked
for a single SCMI message processing and always returns with a
synchronous response message passed back to the caller agent.
This change fixes and updates STM32_COMMON_SIP_NUM_CALLS that was
previously wrongly set 4 whereas only 1 SiP SMC function ID was to
be counted. STM32_COMMON_SIP_NUM_CALLS is now set to 3 since the
2 added SiP SMC function IDs for SCMI services.
Change-Id: Icb428775856b9aec00538172aea4cf11e609b033
Signed-off-by: Etienne Carriere <etienne.carriere@st.com>