fix(msm8916): add timeout for crash console TX flush

Resetting the UART DM controller while there are still remaining
characters in the FIFO often results in corruption on the UART receiver
side. To avoid this the msm8916 crash console implementation tries to
wait until the TX FIFO is empty.

Unfortunately this might spin forever if the transmitter was disabled
before it has fully finished transmitting. In this case the TXEMT bit
console_uartdm_core_flush is waiting for will never get set.

There seems to be no good way to detect if the transmitter is actually
enabled via the status registers. However, the TX FIFO is fairly small
and should not take too long to get flushed, so fix this by simply
limiting the amount of iterations with a short timeout.

Move the code to console_uartdm_core_init to ensure that this always
happens before resetting the transmitter (also during initialization).

Change-Id: I5bb43cb0b6c029bcd15e253d60d36c0b310e108b
Signed-off-by: Stephan Gerhold <stephan@gerhold.net>
This commit is contained in:
Stephan Gerhold 2023-04-06 21:43:37 +02:00 committed by Manish V Badarkhe
parent a27e3f7698
commit 7e002c8a13
2 changed files with 17 additions and 14 deletions

View file

@ -1,5 +1,5 @@
/*
* Copyright (c) 2021, Stephan Gerhold <stephan@gerhold.net>
* Copyright (c) 2021-2023, Stephan Gerhold <stephan@gerhold.net>
*
* SPDX-License-Identifier: BSD-3-Clause
*/
@ -31,17 +31,6 @@
*/
func plat_crash_console_init
mov x1, #BLSP_UART2_BASE
/*
* If the non-secure world has been actively using the UART there might
* be still some characters left to be sent in the FIFO. In that case,
* resetting the transmitter too early might cause all output to become
* corrupted. To avoid that, try to flush (wait until FIFO empty) first.
*/
mov x4, lr
bl console_uartdm_core_flush
mov lr, x4
mov x0, #1
b console_uartdm_core_init
endfunc plat_crash_console_init

View file

@ -1,5 +1,5 @@
/*
* Copyright (c) 2021-2022, Stephan Gerhold <stephan@gerhold.net>
* Copyright (c) 2021-2023, Stephan Gerhold <stephan@gerhold.net>
*
* Based on aarch64/skeleton_console.S:
* Copyright (c) 2015-2020, ARM Limited and Contributors. All rights reserved.
@ -65,7 +65,21 @@ endfunc console_uartdm_register
* -----------------------------------------------------------
*/
func console_uartdm_core_init
/* Reset receiver */
/*
* Try to flush remaining characters from the TX FIFO before resetting
* the transmitter. Unfortunately there is no good way to check if
* the transmitter is actually enabled (and will finish eventually),
* so use a timeout to avoid looping forever.
*/
mov w2, #65536
1:
ldr w3, [x1, #UART_DM_SR]
tbnz w3, #UART_DM_SR_TXEMT_BIT, 2f
subs w2, w2, #1
b.ne 1b
/* Timeout */
2: /* Reset receiver */
mov w3, #UART_DM_CR_RESET_RX
str w3, [x1, #UART_DM_CR]