mirror of
https://github.com/ARM-software/arm-trusted-firmware.git
synced 2025-04-18 02:24:18 +00:00
feat(fdts/morello): add thermal framework
Add thermal zones, cooling maps (passive cooling via DVFS), trip points, etc. for Morello SoC. Change-Id: I5bbc2999a5fd16ebbb3bb2f987eeb42f70961b98 Signed-off-by: Anurag Koul <anurag.koul@arm.com>
This commit is contained in:
parent
abc2919c6c
commit
0b221603e9
1 changed files with 122 additions and 0 deletions
|
@ -35,6 +35,15 @@
|
|||
device_type = "cpu";
|
||||
enable-method = "psci";
|
||||
clocks = <&scmi_dvfs 0>;
|
||||
operating-points = <
|
||||
/* kHz uV */
|
||||
2600000 925000
|
||||
2400000 875000
|
||||
2200000 825000
|
||||
2000000 775000
|
||||
1800000 750000
|
||||
>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
cpu1: cpu1@100 {
|
||||
compatible = "arm,armv8";
|
||||
|
@ -42,6 +51,15 @@
|
|||
device_type = "cpu";
|
||||
enable-method = "psci";
|
||||
clocks = <&scmi_dvfs 0>;
|
||||
operating-points = <
|
||||
/* kHz uV */
|
||||
2600000 925000
|
||||
2400000 875000
|
||||
2200000 825000
|
||||
2000000 775000
|
||||
1800000 750000
|
||||
>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
cpu2: cpu2@10000 {
|
||||
compatible = "arm,armv8";
|
||||
|
@ -49,6 +67,15 @@
|
|||
device_type = "cpu";
|
||||
enable-method = "psci";
|
||||
clocks = <&scmi_dvfs 1>;
|
||||
operating-points = <
|
||||
/* kHz uV */
|
||||
2600000 925000
|
||||
2400000 875000
|
||||
2200000 825000
|
||||
2000000 775000
|
||||
1800000 750000
|
||||
>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
cpu3: cpu3@10100 {
|
||||
compatible = "arm,armv8";
|
||||
|
@ -56,6 +83,15 @@
|
|||
device_type = "cpu";
|
||||
enable-method = "psci";
|
||||
clocks = <&scmi_dvfs 1>;
|
||||
operating-points = <
|
||||
/* kHz uV */
|
||||
2600000 925000
|
||||
2400000 875000
|
||||
2200000 825000
|
||||
2000000 775000
|
||||
1800000 750000
|
||||
>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
};
|
||||
|
||||
|
@ -255,6 +291,92 @@
|
|||
reg = <0x14>;
|
||||
#clock-cells = <1>;
|
||||
};
|
||||
scmi_sensor: protocol@15 {
|
||||
reg = <0x15>;
|
||||
#thermal-sensor-cells = <1>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zones {
|
||||
clus0-thermal {
|
||||
polling-delay-passive = <200>; /* ms */
|
||||
polling-delay = <1000>; /* ms */
|
||||
|
||||
thermal-sensors = <&scmi_sensor 0>;
|
||||
|
||||
trips {
|
||||
clus0_alarm: clus0-alarm {
|
||||
temperature = <85000>; /* millicelsius */
|
||||
hysteresis = <1000>; /* millicelsius */
|
||||
type = "passive";
|
||||
};
|
||||
clus0_shutdown: clus0-shutdown {
|
||||
temperature = <90000>; /* millicelsius */
|
||||
hysteresis = <0>; /* millicelsius */
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&clus0_alarm>;
|
||||
cooling-device = <&cpu0 4 4>, <&cpu1 4 4>;
|
||||
};
|
||||
};
|
||||
};
|
||||
clus1-thermal {
|
||||
polling-delay-passive = <200>; /* ms */
|
||||
polling-delay = <1000>; /* ms */
|
||||
|
||||
thermal-sensors = <&scmi_sensor 1>;
|
||||
trips {
|
||||
clus1_alarm: clus1-alarm {
|
||||
temperature = <85000>; /* millicelsius */
|
||||
hysteresis = <1000>; /* millicelsius */
|
||||
type = "passive";
|
||||
};
|
||||
clus1_shutdown: clus1-shutdown {
|
||||
temperature = <90000>; /* millicelsius */
|
||||
hysteresis = <0>; /* millicelsius */
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&clus1_alarm>;
|
||||
cooling-device = <&cpu2 4 4>, <&cpu3 4 4>;
|
||||
};
|
||||
};
|
||||
};
|
||||
sys-thermal {
|
||||
polling-delay-passive = <200>; /* ms */
|
||||
polling-delay = <1000>; /* ms */
|
||||
|
||||
thermal-sensors = <&scmi_sensor 2>;
|
||||
trips {
|
||||
sys_alarm: sys-alarm {
|
||||
temperature = <85000>; /* millicelsius */
|
||||
hysteresis = <1000>; /* millicelsius */
|
||||
type = "passive";
|
||||
};
|
||||
sys_shutdown: sys-shutdown {
|
||||
temperature = <90000>; /* millicelsius */
|
||||
hysteresis = <0>; /* millicelsius */
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&sys_alarm>;
|
||||
cooling-device = <&cpu0 4 4>,
|
||||
<&cpu1 4 4>,
|
||||
<&cpu2 4 4>,
|
||||
<&cpu3 4 4>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
|
|
Loading…